Oilfield Instrumentation’s Drill Gas 1000 system is designed with the accuracy and reliability of our infrared gas sensor along with a user-friendly office interface. The driller has a daylight viewable numeric LCD display with alarm set points. The office user has the luxury of having a PC-based acquisition program allowing the user to view a real-time numeric and graphical display. The user also has the option of viewing and/or printing historical data. Each user has the ability to set individual alarm points.
This system consists of:
- Laptop or PC-based remote with printer
- Simrad infrared gas sensor
- Hydrocarbon filter – keeps lens clean
- Regulated blow-back system
- Gas trap – uses air (120 PSI)
- Airflow regulator
- Oiler – to lubricate trap
- Daylight viewable LCD numeric display
- Sun visor
- Gas sensor voltages
– Input 24 VDC
– Output 4-20 mA signal